## On-Board LEDs
| LED number | Color | Software control | Remarks |
|------------|-------|------------------|---------|
| LED1 | Green | Yes | Active-low |
| LED2 | Red | Yes | Active-low |
| LED3 | Green | Yes | Active-low |
| LED4 | Green | Yes | Active-low |
| LED5 | Green | Yes | Active-low |
| LED6 | Green | Yes | Active-low |
| LED7 | Green | Yes | Active-low |
| LED8 | Green | No | Power indicator |
!!! info
2018-12-07 05:38:47 +01:00
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
2018-12-07 04:17:40 +01:00
## Expansion Panel (J18)
2018-12-07 04:17:40 +01:00
Helios4 board was designed to either use the on-board LEDs or use a custom expansion panel (not-available).
2018-12-07 05:38:47 +01:00
If you wish to use the header, insure to switch to OFF the Dip Switch SW2.
![Dipswitch LED](/helios4/img/led/dipswitch_led_off.png)
### Pinout Table
![J18 Pinout](/helios4/img/led/gpio_pinout_j18.png)
| Pin | LED number | Remarks |
2018-12-07 04:17:40 +01:00
|-----|------------|---------|
| 1 | - | 3.3V supply |
| 2 | - | Not connected |
| 3 | LED1 | Active-low |
| 4 | LED2 | Active-low |
| 5 | LED3 | Active-low |
| 6 | LED4 | Active-low |
| 7 | LED5 | Active-low |
| 8 | LED6 | Active-low |
| 9 | LED7 | Active-low |
| 10 | - | GND |
!!! info
2018-12-07 05:38:47 +01:00
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
2018-12-07 04:17:40 +01:00
### Wiring Diagram
Since the signals to control the LEDs are active low, connect the pin to LED's cathode.
2018-12-07 05:38:47 +01:00
Below a wiring diagram example.
2018-12-07 04:17:40 +01:00
![Wiring Example](/helios4/img/led/led_expansion_wiring_diagram.png)
2018-12-07 04:17:40 +01:00
## LED under Linux
| LED | Name | Default Trigger | Remarks |
|------|----------------------|-----------------|---------|
| LED1 | helios4:green:status | heartbeat | Blinking periodically |
| LED2 | helios4:red:fault | none | See [Configuring Fault LED](#configuring-fault-led) |
| LED3 | helios4:green:ata1 | ata1 | Blinking on SATA1 activity |
| LED4 | helios4:green:ata2 | ata2 | Blinking on SATA2 activity |
| LED5 | helios4:green:ata3 | ata3 | Blinking on SATA3 activity |
| LED6 | helios4:green:ata4 | ata4 | Blinking on SATA4 activity |
| LED7 | helios4:green:usb | usb-host | Blinking on USB activity, any port |
!!! note
**ata** trigger requires additional patch to mainline kernel. The patch can be found [here](/helios4/files/led/libata_leds_trigger_mvebu.patch). **Armbian** builds are already patched, so no action is required.
2018-12-07 04:17:40 +01:00
2018-12-07 05:38:47 +01:00
The LEDs can be accessed under LEDs class in *sysfs*.
2018-12-07 04:17:40 +01:00
```
root@helios4:~/# ls -l /sys/class/leds/
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata1 -> ../../devices/platform/io-leds/leds/helios4:green:ata1
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata2 -> ../../devices/platform/io-leds/leds/helios4:green:ata2
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata3 -> ../../devices/platform/io-leds/leds/helios4:green:ata3
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata4 -> ../../devices/platform/io-leds/leds/helios4:green:ata4
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:status -> ../../devices/platform/system-leds/leds/helios4:green:status
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:usb -> ../../devices/platform/io-leds/leds/helios4:green:usb
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:red:fault -> ../../devices/platform/system-leds/leds/helios4:red:fault
```
### LEDs Trigger
- none
No automatic trigger. Manually control the LED by manipulating "brightness".
More info see [Configuring LED trigger](#configuring-led-trigger).
- heartbeat
2018-12-07 05:38:47 +01:00
LED "double" flashes at a load average based rate. The interval might change during heavy load.
If the LED no longer blinks, it means the system is locked-up or hung and has to be reset.
2018-12-07 04:17:40 +01:00
2018-12-07 05:38:47 +01:00
- ata*N*
2018-12-07 04:17:40 +01:00
2018-12-07 05:38:47 +01:00
LED blinks on any read/write activity at specific SATA port.
2018-12-07 04:17:40 +01:00
- usb-host
2018-12-07 05:38:47 +01:00
LED blinks on USB activity at any port.
2018-12-07 04:17:40 +01:00
- panic
This trigger allows LEDs to be configured to blink on a kernel panic.
- timer
2018-12-07 05:38:47 +01:00
This allows LEDs to be controlled by a programmable timer via *sysfs*. delay_on to set how long
the LED turned on and delay_off to set how long the LED turned off.
2018-12-07 04:17:40 +01:00
### Configuring LED trigger
2018-12-07 05:38:47 +01:00
To configure, simply set the trigger type. For example to set Status LED triggered by timer
2018-12-07 04:17:40 +01:00
```
echo timer | sudo tee -a /sys/class/leds/helios4\:green\:status/trigger
```
2018-12-07 05:38:47 +01:00
Some of the triggers may expose additional parameters that can be configured further.
2018-12-07 04:17:40 +01:00
2018-12-07 05:38:47 +01:00
On **none** trigger, to turn ON the LED set the brightness bigger than 0.
2018-12-07 04:17:40 +01:00
```
echo 1 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
```
2018-12-07 05:38:47 +01:00
and to turn OFF the LED set the brightness to 0.
2018-12-07 04:17:40 +01:00
```
echo 0 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
```
2018-12-07 05:38:47 +01:00
On **timer** trigger, it will exposed *delay_on* and *delay_off* with default value of 0.5 seconds for both.
2018-12-07 04:17:40 +01:00
To change the delay, set the respective parameter (value in milliseconds)
```
echo 1000 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_on
echo 200 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_off
```
!!! note
The changes is not retained across reboot. Use startup script or udev rules to make it permanent.
### Configuring Fault LED
While other LEDs are preconfigured, the fault LED remains unconfigured (trigger:**none**).
#### 1. As Kernel Panic Indicator
2018-12-07 05:38:47 +01:00
To configure the LED as Kernel panic indicator, set the trigger to **panic**. However this functionality might be redundant with Status LED, since if a kernel panic occurs and/or system hangs, the Status LED will no longer blink.
2018-12-07 04:17:40 +01:00
To trigger kernel panic to test the LED, run
```
echo c > /proc/sysrq-trigger
```
!!! warning
Triggering kernel panic can lead to data loss. Use with caution!
2018-12-07 05:38:47 +01:00
#### 2. As RAID Fault Indicator
2018-12-07 04:17:40 +01:00
To configure the LED as RAID fault indicator, please refer to [MDADM: Configure Fault LED](/helios4/mdadm/#configure-fault-led)
2018-12-07 04:17:40 +01:00
2018-12-07 05:38:47 +01:00
!!! note
On Armbian builds, this is the default setting for fault LED.