@ -45,6 +45,7 @@ The term *duty cycle* describes the proportion of 'on' time to the regular inter
| Description | Header J10 | Header J17 | Remarks | | Description | Header J10 | Header J17 | Remarks |
|-----------|---------|-----------|---------| |-----------|---------|-----------|---------|
| PWM pin | gpio41 | gpio55 | 5V tolerant |
| SENSE pin | gpio43 | gpio48 | SENSE pin is not implemented yet | | SENSE pin | gpio43 | gpio48 | SENSE pin is not implemented yet |
| PWM Frequency | 25 kHz | 25 kHz | defined in device tree | | PWM Frequency | 25 kHz | 25 kHz | defined in device tree |
@ -187,21 +188,21 @@ fancontrol includes *pwmconfig* script to create automatically a configuration f
Since hwmon order can be changed between kernel version or even between reboot, on Armbian we use udev rules as workaround. The rules can be found from [here](https://raw.githubusercontent.com/armbian/build/master/packages/bsp/helios4/90-helios4-hwmon.rules) and to be copy to **/etc/udev/rules.d/** Since hwmon order can be changed between kernel version or even between reboot, on Armbian we use udev rules as workaround. The rules can be found from [here](https://raw.githubusercontent.com/armbian/build/master/packages/bsp/helios4/90-helios4-hwmon.rules) and to be copy to **/etc/udev/rules.d/**
*/dev/fan-j10, /dev/fan-j17, /dev/thermal-cpu, /dev/thermal-board,* and */dev/thermal-eth* are symlinks generated by the udev rules.
#### Configuration File #### Configuration File
fancontrol uses **/etc/fancontrol** as configuration file. Below is an example configuration to control fan speed on Helios4. fancontrol uses **/etc/fancontrol** as configuration file. Below is an example configuration to control fan speed on Helios4.
``` ```
# Helios4 PWM Fan Control Configuration # Helios4 PWM Fan Control Configuration
# Temp source : armada_thermal sensor # Temp source : /dev/thermal-cpu
INTERVAL=10 INTERVAL=10
DEVPATH=hwmon3=devices/platform/j10-pwm hwmon4=devices/platform/j17-pwm hwmon2=devices/platform/soc/soc:internal-regs/f1011000.i2c/i2c-0/0-004c FCTEMPS=/dev/fan-j10/pwm1=/dev/thermal-cpu/temp1_input /dev/fan-j17/pwm1=/dev/thermal-cpu/temp1_input
DEVNAME=hwmon1=f10e4078.thermal MINTEMP=/dev/fan-j10/pwm1=40 /dev/fan-j17/pwm1=40
FCTEMPS=hwmon3/pwm1=hwmon1/temp1_input hwmon4/pwm1=hwmon1/temp1_input MAXTEMP=/dev/fan-j10/pwm1=80 /dev/fan-j17/pwm1=80
MINTEMP=hwmon3/pwm1=40 hwmon4/pwm1=40 MINSTART=/dev/fan-j10/pwm1=20 /dev/fan-j17/pwm1=20
MAXTEMP=hwmon3/pwm1=80 hwmon4/pwm1=80 MINSTOP=/dev/fan-j10/pwm1=29 /dev/fan-j17/pwm1=29
MINSTART=hwmon3/pwm1=20 hwmon4/pwm1=20
MINSTOP=hwmon3/pwm1=29 hwmon4/pwm1=29
MINPWM=20 MINPWM=20
``` ```
@ -209,23 +210,11 @@ INTERVAL
This variable defines at which interval in seconds the main loop of fancontrol will be executed. This variable defines at which interval in seconds the main loop of fancontrol will be executed.
DEVPATH
Maps hwmon class devices to physical devices. This lets fancontrol check that the configuration file is still up-to-date.
It expect the **hwmonN** as symlink to **devices/***
DEVNAME
Records hwmon class device names. This lets fancontrol check that the configuration file is still up-to-date.
Since **armada_thermal** does not create symlink, use *DEVNAME* instead of *DEVPATH*
FCTEMPS FCTEMPS
Maps PWM outputs to temperature sensors so fancontrol knows which temperature sensors should be used for calculation of new values for the corresponding PWM outputs. Maps PWM outputs to temperature sensors so fancontrol knows which temperature sensors should be used for calculation of new values for the corresponding PWM outputs.
Fans (**hwmon3** & **hwmon4**) are controlled based on CPU thermal sensor (**hwmon1**) reading. Fans (**fan-j10** & **fan-j17**) are controlled based on CPU thermal sensor (**thermal-cpu**) reading.
MINSTART MINSTART
@ -247,13 +236,13 @@ MINTEMP
The temperature below which the fan gets switched to minimum speed. The temperature below which the fan gets switched to minimum speed.
Fans (hwmon2 & hwmon3) runs in minimum speed if the CPU temperature below **40** degree C. Fans (fan-j10 & fan-j17) runs in minimum speed if the CPU temperature below **40** degree C.
MAXTEMP MAXTEMP
The temperature over which the fan gets switched to maximum speed. The temperature over which the fan gets switched to maximum speed.
Fans (hwmon2 & hwmon3) runs in maximum speed if the CPU temperature above **80** degree C. Fans (fan-j10 & fan-j17) runs in maximum speed if the CPU temperature above **80** degree C.
MINPWM MINPWM