diff --git a/docs/helios64/hardware.md b/docs/helios64/hardware.md
index 606aa94..56a96d7 100644
--- a/docs/helios64/hardware.md
+++ b/docs/helios64/hardware.md
@@ -64,12 +64,13 @@ This block diagram is cited from the RK3399 website documentation. [1](http://op
| State | DC measured
power consumption | AC calculated
power consumption | Remarks |
|---|---|---|---|
-| Idle | 25.2 W | 29 W | |
-| CPU Load | 31.2 W | 35.9 W | stress-ng (all cores) |
-| HDD Read | 36 W | 41.4 W | dd read (no caching) from RAID6 array|
-| HDD Write | 34.8 W | 40 W | dd write (no caching) to RAID6 array |
-| Network Access | 33.6 W | 38.6 W | HTTP download from RAID6 array |
-| Stress Test | 40.8 W | 47 W | stress-ng (all cores) + fio (all disks) + iperf |
+| Idle | 25.2 W | 29 W | |
+| Suspend | 8.4 W | 9.7 W | Suspend-to-RAM, HDD in Standby mode |
+| CPU Load | 31.2 W | 35.9 W | stress-ng (all cores) |
+| HDD Read | 36 W | 41.4 W | dd read (no caching) from RAID6 array|
+| HDD Write | 34.8 W | 40 W | dd write (no caching) to RAID6 array |
+| Network Access | 33.6 W | 38.6 W | HTTP download from RAID6 array |
+| Stress Test | 40.8 W | 47 W | stress-ng (all cores) + fio (all disks) + iperf |
!!! note
Measures were done using a Current Clamp Meter on the Helios64 12V DC input. AC Power consumption is calculated based on a AC/DC conversion efficiency of 85%.