DK60TPLight/Kicad/MATRIX.sch

2247 lines
58 KiB
Text
Raw Normal View History

2017-06-14 19:41:04 +02:00
EESchema Schematic File Version 2
LIBS:keyboard_parts
LIBS:DK60TP-cache
2017-06-14 19:41:04 +02:00
EELAYER 25 0
EELAYER END
$Descr A4 11693 8268
encoding utf-8
Sheet 5 7
Title "DK60TP"
Date "2017-10-14"
Rev "B"
Comp "DarKou.fr"
2017-06-14 19:41:04 +02:00
Comment1 ""
Comment2 ""
Comment3 ""
Comment4 ""
$EndDescr
Text GLabel 1250 600 0 60 Input ~ 0
Col0
Text GLabel 1950 600 0 60 Input ~ 0
Col1
Text GLabel 2650 600 0 60 Input ~ 0
Col2
Text GLabel 5450 600 0 60 Input ~ 0
Col6
Text GLabel 6150 600 0 60 Input ~ 0
Col7
Text GLabel 6850 600 0 60 Input ~ 0
Col8
Text GLabel 7550 600 0 60 Input ~ 0
Col9
Text GLabel 8250 600 0 60 Input ~ 0
ColA
Text GLabel 8950 600 0 60 Input ~ 0
ColB
Text GLabel 9650 600 0 60 Input ~ 0
ColC
Text GLabel 10350 600 0 60 Input ~ 0
ColD
Text GLabel 4750 600 0 60 Input ~ 0
Col5
2017-10-09 00:00:25 +02:00
Text GLabel 4050 600 0 60 Input ~ 0
2017-06-14 19:41:04 +02:00
Col4
Text GLabel 3350 600 0 60 Input ~ 0
Col3
Text GLabel 10600 6400 2 60 Input ~ 0
Row4
Text GLabel 10600 5000 2 60 Input ~ 0
Row3
Text GLabel 10600 3650 2 60 Input ~ 0
Row2
Text GLabel 10600 2250 2 60 Input ~ 0
Row1
Text GLabel 10600 1450 2 60 Input ~ 0
Row0
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K0
2017-06-14 19:41:04 +02:00
U 1 1 593001BE
2017-10-09 00:00:25 +02:00
P 950 900
F 0 "K0" H 900 900 60 0001 C CNN
F 1 "K00" H 950 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 950 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 950 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 950 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K100
2017-06-14 19:41:04 +02:00
U 1 1 593008D3
2017-10-09 00:00:25 +02:00
P 1650 900
F 0 "K100" H 1600 900 60 0001 C CNN
F 1 "K01" H 1650 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 1650 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 1650 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K200
2017-06-14 19:41:04 +02:00
U 1 1 59300923
2017-10-09 00:00:25 +02:00
P 2350 900
F 0 "K200" H 2300 900 60 0001 C CNN
F 1 "K02" H 2350 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 2350 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 2350 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K300
2017-06-14 19:41:04 +02:00
U 1 1 59300973
2017-10-09 00:00:25 +02:00
P 3050 900
F 0 "K300" H 3000 900 60 0001 C CNN
F 1 "K03" H 3050 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3050 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3050 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 3050 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K400
2017-06-14 19:41:04 +02:00
U 1 1 593009C3
2017-10-09 00:00:25 +02:00
P 3750 900
F 0 "K400" H 3700 900 60 0001 C CNN
F 1 "K04" H 3750 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3750 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3750 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 3750 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K500
2017-06-14 19:41:04 +02:00
U 1 1 59300A13
2017-10-09 00:00:25 +02:00
P 4450 900
F 0 "K500" H 4400 900 60 0001 C CNN
F 1 "K05" H 4450 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 4450 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 4450 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 4450 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K600
2017-06-14 19:41:04 +02:00
U 1 1 59302751
2017-10-09 00:00:25 +02:00
P 5150 900
F 0 "K600" H 5100 900 60 0001 C CNN
F 1 "K06" H 5150 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5150 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 5150 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K700
2017-06-14 19:41:04 +02:00
U 1 1 593027A1
2017-10-09 00:00:25 +02:00
P 5850 900
F 0 "K700" H 5800 900 60 0001 C CNN
F 1 "K07" H 5850 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5850 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5850 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 5850 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K800
2017-06-14 19:41:04 +02:00
U 1 1 593027F1
2017-10-09 00:00:25 +02:00
P 6550 900
F 0 "K800" H 6500 900 60 0001 C CNN
F 1 "K08" H 6550 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 6550 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 6550 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 6550 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K900
2017-06-14 19:41:04 +02:00
U 1 1 59302841
2017-10-09 00:00:25 +02:00
P 7250 900
F 0 "K900" H 7200 900 60 0001 C CNN
F 1 "K09" H 7250 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7250 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7250 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 7250 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KA0
2017-06-14 19:41:04 +02:00
U 1 1 59305CFF
2017-10-09 00:00:25 +02:00
P 7950 900
F 0 "KA0" H 7900 900 60 0001 C CNN
F 1 "K0A" H 7950 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7950 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 7950 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB0
2017-06-14 19:41:04 +02:00
U 1 1 5930751E
2017-10-09 00:00:25 +02:00
P 8650 900
F 0 "KB0" H 8600 900 60 0001 C CNN
F 1 "K0B" H 8650 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 8650 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 8650 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC0
2017-06-14 19:41:04 +02:00
U 1 1 593075D5
2017-10-09 00:00:25 +02:00
P 9350 900
F 0 "KC0" H 9300 900 60 0001 C CNN
F 1 "K0C" H 9350 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 9350 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 9350 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD0
2017-06-14 19:41:04 +02:00
U 1 1 59307625
2017-10-09 00:00:25 +02:00
P 10050 900
F 0 "KD0" H 10000 900 60 0001 C CNN
F 1 "K0D" H 10050 800 60 0000 C CNN
F 2 "Footprint:Mx_100" H 10050 900 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 900 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-17 00:47:04 +02:00
1 10050 900
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD1
2017-06-14 19:41:04 +02:00
U 1 1 5931051C
2017-10-09 00:00:25 +02:00
P 10050 1200
F 0 "KD1" H 10000 1200 60 0001 C CNN
F 1 "K0D" H 10050 1100 60 0000 C CNN
F 2 "Footprint:Mx_200" H 10050 1200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 1200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 1200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K10
2017-06-14 19:41:04 +02:00
U 1 1 5931B739
2017-10-09 00:00:25 +02:00
P 950 2000
F 0 "K10" H 900 2000 60 0001 C CNN
F 1 "K10" H 950 1900 60 0000 C CNN
F 2 "Footprint:Mx_150" H 950 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K110
2017-06-14 19:41:04 +02:00
U 1 1 5931B740
2017-10-09 00:00:25 +02:00
P 1650 2000
F 0 "K110" H 1600 2000 60 0001 C CNN
F 1 "K11" H 1650 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 1650 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 1650 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K210
2017-06-14 19:41:04 +02:00
U 1 1 5931B746
2017-10-09 00:00:25 +02:00
P 2350 2000
F 0 "K210" H 2300 2000 60 0001 C CNN
F 1 "K12" H 2350 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 2350 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 2350 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K310
2017-06-14 19:41:04 +02:00
U 1 1 5931B74C
2017-10-09 00:00:25 +02:00
P 3050 2000
F 0 "K310" H 3000 2000 60 0001 C CNN
F 1 "K13" H 3050 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3050 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3050 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3050 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K410
2017-06-14 19:41:04 +02:00
U 1 1 5931B752
2017-10-09 00:00:25 +02:00
P 3750 2000
F 0 "K410" H 3700 2000 60 0001 C CNN
F 1 "K14" H 3750 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3750 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3750 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3750 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K510
2017-06-14 19:41:04 +02:00
U 1 1 5931B758
2017-10-09 00:00:25 +02:00
P 4450 2000
F 0 "K510" H 4400 2000 60 0001 C CNN
F 1 "K15" H 4450 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 4450 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 4450 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 4450 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K610
2017-06-14 19:41:04 +02:00
U 1 1 5931B75E
2017-10-09 00:00:25 +02:00
P 5150 2000
F 0 "K610" H 5100 2000 60 0001 C CNN
F 1 "K16" H 5150 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5150 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K710
2017-06-14 19:41:04 +02:00
U 1 1 5931B764
2017-10-09 00:00:25 +02:00
P 5850 2000
F 0 "K710" H 5800 2000 60 0001 C CNN
F 1 "K17" H 5850 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5850 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5850 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5850 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K810
2017-06-14 19:41:04 +02:00
U 1 1 5931B76A
2017-10-09 00:00:25 +02:00
P 6550 2000
F 0 "K810" H 6500 2000 60 0001 C CNN
F 1 "K18" H 6550 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 6550 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 6550 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 6550 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K910
2017-06-14 19:41:04 +02:00
U 1 1 5931B770
2017-10-09 00:00:25 +02:00
P 7250 2000
F 0 "K910" H 7200 2000 60 0001 C CNN
F 1 "K19" H 7250 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7250 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7250 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7250 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KA10
2017-06-14 19:41:04 +02:00
U 1 1 5931B776
2017-10-09 00:00:25 +02:00
P 7950 2000
F 0 "KA10" H 7900 2000 60 0001 C CNN
F 1 "K1A" H 7950 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7950 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7950 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB10
2017-06-14 19:41:04 +02:00
U 1 1 5931B77C
2017-10-09 00:00:25 +02:00
P 8650 2000
F 0 "KB10" H 8600 2000 60 0001 C CNN
F 1 "K1B" H 8650 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 8650 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC10
2017-06-14 19:41:04 +02:00
U 1 1 5931B782
2017-10-09 00:00:25 +02:00
P 9350 2000
F 0 "KC10" H 9300 2000 60 0001 C CNN
F 1 "K1C" H 9350 1900 60 0000 C CNN
F 2 "Footprint:Mx_100" H 9350 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD10
2017-06-14 19:41:04 +02:00
U 1 1 5931B788
2017-10-09 00:00:25 +02:00
P 10050 2000
F 0 "KD10" H 10000 2000 60 0001 C CNN
F 1 "K1D" H 10050 1900 60 0000 C CNN
F 2 "Footprint:Mx_150" H 10050 2000 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 2000 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 2000
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K20
2017-06-14 19:41:04 +02:00
U 1 1 59346A83
2017-10-09 00:00:25 +02:00
P 950 2800
F 0 "K20" H 900 2800 60 0001 C CNN
F 1 "K20" H 950 2700 60 0000 C CNN
F 2 "Footprint:Mx_175" H 950 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K120
2017-06-14 19:41:04 +02:00
U 1 1 59346A8A
2017-10-09 00:00:25 +02:00
P 1650 2800
F 0 "K120" H 1600 2800 60 0001 C CNN
F 1 "K21" H 1650 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 1650 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 1650 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K220
2017-06-14 19:41:04 +02:00
U 1 1 59346A90
2017-10-09 00:00:25 +02:00
P 2350 2800
F 0 "K220" H 2300 2800 60 0001 C CNN
F 1 "K22" H 2350 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 2350 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 2350 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K320
2017-06-14 19:41:04 +02:00
U 1 1 59346A96
2017-10-09 00:00:25 +02:00
P 3050 2800
F 0 "K320" H 3000 2800 60 0001 C CNN
F 1 "K23" H 3050 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3050 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3050 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3050 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K420
2017-06-14 19:41:04 +02:00
U 1 1 59346A9C
2017-10-09 00:00:25 +02:00
P 3750 2800
F 0 "K420" H 3700 2800 60 0001 C CNN
F 1 "K24" H 3750 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3750 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3750 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3750 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K520
2017-06-14 19:41:04 +02:00
U 1 1 59346AA2
2017-10-09 00:00:25 +02:00
P 4450 2800
F 0 "K520" H 4400 2800 60 0001 C CNN
F 1 "K25" H 4450 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 4450 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 4450 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 4450 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K620
2017-06-14 19:41:04 +02:00
U 1 1 59346AA8
2017-10-09 00:00:25 +02:00
P 5150 2800
F 0 "K620" H 5100 2800 60 0001 C CNN
F 1 "K26" H 5150 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5150 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K720
2017-06-14 19:41:04 +02:00
U 1 1 59346AAE
2017-10-09 00:00:25 +02:00
P 5850 2800
F 0 "K720" H 5800 2800 60 0001 C CNN
F 1 "K27" H 5850 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5850 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5850 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5850 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K820
2017-06-14 19:41:04 +02:00
U 1 1 59346AB4
2017-10-09 00:00:25 +02:00
P 6550 2800
F 0 "K820" H 6500 2800 60 0001 C CNN
F 1 "K28" H 6550 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 6550 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 6550 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 6550 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K920
2017-06-14 19:41:04 +02:00
U 1 1 59346ABA
2017-10-09 00:00:25 +02:00
P 7250 2800
F 0 "K920" H 7200 2800 60 0001 C CNN
F 1 "K29" H 7250 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7250 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7250 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7250 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KA20
2017-06-14 19:41:04 +02:00
U 1 1 59346AC0
2017-10-09 00:00:25 +02:00
P 7950 2800
F 0 "KA20" H 7900 2800 60 0001 C CNN
F 1 "K2A" H 7950 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7950 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7950 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB20
2017-06-14 19:41:04 +02:00
U 1 1 59346AC6
2017-10-09 00:00:25 +02:00
P 8650 2800
F 0 "KB20" H 8600 2800 60 0001 C CNN
F 1 "K2B" H 8650 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 8650 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC20
2017-06-14 19:41:04 +02:00
U 1 1 59346ACC
2017-10-09 00:00:25 +02:00
P 9350 2800
F 0 "KC20" H 9300 2800 60 0001 C CNN
F 1 "K2C" H 9350 2700 60 0000 C CNN
F 2 "Footprint:Mx_100" H 9350 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD21
2017-06-14 19:41:04 +02:00
U 1 1 59346AD2
2017-10-09 00:00:25 +02:00
P 10050 3100
F 0 "KD21" H 10000 3100 60 0001 C CNN
F 1 "K2D" H 10050 3000 60 0001 C CNN
F 2 "Footprint:Mx_225" H 10050 3100 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 3100 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
F 5 "ANSI ENTER" H 10050 3100 60 0001 C CNN "Comment"
2017-10-09 00:00:25 +02:00
1 10050 3100
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD22
2017-06-14 19:41:04 +02:00
U 1 1 59346AD9
2017-10-09 00:00:25 +02:00
P 10050 3400
F 0 "KD22" H 10000 3400 60 0001 C CNN
F 1 "K2D" H 10050 3300 60 0001 C CNN
F 2 "Footprint:Mx_200" H 10050 3400 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 3400 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
F 5 "ISO Enter" H 10050 3400 60 0001 C CNN "Comment"
2017-10-09 00:00:25 +02:00
1 10050 3400
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K21
2017-06-14 19:41:04 +02:00
U 1 1 59346EC0
2017-10-09 00:00:25 +02:00
P 950 3100
F 0 "K21" H 900 3100 60 0001 C CNN
F 1 "K20" H 950 3000 60 0001 C CNN
F 2 "Footprint:Mx_175_STEPPED" H 950 3100 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 3100 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 3100
2017-10-17 00:47:04 +02:00
-1 0 0 1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K30
2017-06-14 19:41:04 +02:00
U 1 1 59357231
2017-10-09 00:00:25 +02:00
P 950 4200
F 0 "K30" H 900 4200 60 0001 C CNN
F 1 "K30" H 950 4100 60 0000 C CNN
F 2 "Footprint:Mx_225" H 950 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K130
2017-06-14 19:41:04 +02:00
U 1 1 59357237
2017-10-09 00:00:25 +02:00
P 1650 4200
F 0 "K130" H 1600 4200 60 0001 C CNN
F 1 "K31" H 1650 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 1650 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 1650 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K230
2017-06-14 19:41:04 +02:00
U 1 1 5935723D
2017-10-09 00:00:25 +02:00
P 2350 4200
F 0 "K230" H 2300 4200 60 0001 C CNN
F 1 "K32" H 2350 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 2350 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 2350 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K330
2017-06-14 19:41:04 +02:00
U 1 1 59357243
2017-10-09 00:00:25 +02:00
P 3050 4200
F 0 "K330" H 3000 4200 60 0001 C CNN
F 1 "K33" H 3050 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3050 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3050 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3050 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K430
2017-06-14 19:41:04 +02:00
U 1 1 59357249
2017-10-09 00:00:25 +02:00
P 3750 4200
F 0 "K430" H 3700 4200 60 0001 C CNN
F 1 "K34" H 3750 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 3750 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 3750 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 3750 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K530
2017-06-14 19:41:04 +02:00
U 1 1 5935724F
2017-10-09 00:00:25 +02:00
P 4450 4200
F 0 "K530" H 4400 4200 60 0001 C CNN
F 1 "K35" H 4450 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 4450 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 4450 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 4450 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K630
2017-06-14 19:41:04 +02:00
U 1 1 59357255
2017-10-09 00:00:25 +02:00
P 5150 4200
F 0 "K630" H 5100 4200 60 0001 C CNN
F 1 "K36" H 5150 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5150 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K730
2017-06-14 19:41:04 +02:00
U 1 1 5935725B
2017-10-09 00:00:25 +02:00
P 5850 4200
F 0 "K730" H 5800 4200 60 0001 C CNN
F 1 "K37" H 5850 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 5850 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5850 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5850 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K830
2017-06-14 19:41:04 +02:00
U 1 1 59357261
2017-10-09 00:00:25 +02:00
P 6550 4200
F 0 "K830" H 6500 4200 60 0001 C CNN
F 1 "K38" H 6550 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 6550 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 6550 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 6550 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K930
2017-06-14 19:41:04 +02:00
U 1 1 59357267
2017-10-09 00:00:25 +02:00
P 7250 4200
F 0 "K930" H 7200 4200 60 0001 C CNN
F 1 "K39" H 7250 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7250 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7250 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7250 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KA30
2017-06-14 19:41:04 +02:00
U 1 1 5935726D
2017-10-09 00:00:25 +02:00
P 7950 4200
F 0 "KA30" H 7900 4200 60 0001 C CNN
F 1 "K3A" H 7950 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7950 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7950 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB30
2017-06-14 19:41:04 +02:00
U 1 1 59357273
2017-10-09 00:00:25 +02:00
P 8650 4200
F 0 "KB30" H 8600 4200 60 0001 C CNN
F 1 "K3B" H 8650 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 8650 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC30
2017-06-14 19:41:04 +02:00
U 1 1 59357279
2017-10-09 00:00:25 +02:00
P 9350 4200
F 0 "KC30" H 9300 4200 60 0001 C CNN
F 1 "K3C" H 9350 4100 60 0000 C CNN
F 2 "Footprint:Mx_275" H 9350 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 4200
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD30
2017-06-14 19:41:04 +02:00
U 1 1 5935727F
2017-10-09 00:00:25 +02:00
P 10050 4200
F 0 "KD30" H 10000 4200 60 0001 C CNN
F 1 "K3D" H 10050 4100 60 0000 C CNN
F 2 "Footprint:Mx_100" H 10050 4200 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 4200 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 4200
2017-10-17 00:47:04 +02:00
-1 0 0 1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC32
2017-06-14 19:41:04 +02:00
U 1 1 59357286
2017-10-09 00:00:25 +02:00
P 9350 4750
F 0 "KC32" H 9300 4750 60 0001 C CNN
F 1 "K3C" H 9350 4650 60 0001 C CNN
F 2 "Footprint:Mx_175" H 9350 4750 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 4750 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 4750
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K31
2017-06-14 19:41:04 +02:00
U 1 1 59357310
2017-10-09 00:00:25 +02:00
P 950 4450
F 0 "K31" H 900 4450 60 0001 C CNN
F 1 "K30" H 950 4350 60 0001 C CNN
F 2 "Footprint:Mx_125" H 950 4450 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 4450 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 4450
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K40
2017-06-14 19:41:04 +02:00
U 1 1 59376C98
2017-10-09 00:00:25 +02:00
P 950 5550
F 0 "K40" H 900 5550 60 0001 C CNN
F 1 "K40" H 950 5450 60 0000 C CNN
F 2 "Footprint:Mx_125" H 950 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K41
2017-06-14 19:41:04 +02:00
U 1 1 59376D90
2017-10-09 00:00:25 +02:00
P 950 5850
F 0 "K41" H 900 5850 60 0001 C CNN
F 1 "K40" H 950 5750 60 0001 C CNN
F 2 "Footprint:Mx_150" H 950 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 950 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 950 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K140
2017-06-14 19:41:04 +02:00
U 1 1 5937DE9B
2017-10-09 00:00:25 +02:00
P 1650 5550
F 0 "K140" H 1600 5550 60 0001 C CNN
F 1 "K41" H 1650 5450 60 0000 C CNN
F 2 "Footprint:Mx_125" H 1650 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 1650 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K141
2017-06-14 19:41:04 +02:00
U 1 1 5937E2C8
2017-10-09 00:00:25 +02:00
P 1650 5850
F 0 "K141" H 1600 5850 60 0001 C CNN
F 1 "K41" H 1650 5750 60 0001 C CNN
F 2 "Footprint:Mx_100" H 1650 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 1650 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 1650 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K240
2017-06-14 19:41:04 +02:00
U 1 1 5937F0E0
2017-10-09 00:00:25 +02:00
P 2350 5550
F 0 "K240" H 2300 5550 60 0001 C CNN
F 1 "K42" H 2350 5450 60 0000 C CNN
F 2 "Footprint:Mx_125" H 2350 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 2350 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K640
2017-06-14 19:41:04 +02:00
U 1 1 593861DC
2017-10-09 00:00:25 +02:00
P 5150 5550
F 0 "K640" H 5100 5550 60 0001 C CNN
F 1 "K46" H 5150 5450 60 0000 C CNN
F 2 "Footprint:Mx_600" H 5150 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K641
2017-06-14 19:41:04 +02:00
U 1 1 59386549
2017-10-09 00:00:25 +02:00
P 5150 5850
F 0 "K641" H 5100 5850 60 0001 C CNN
F 1 "K46" H 5150 5750 60 0001 C CNN
F 2 "Footprint:Mx_625" H 5150 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 5850
2017-10-17 00:47:04 +02:00
-1 0 0 1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K642
2017-06-14 19:41:04 +02:00
U 1 1 59386653
2017-10-09 00:00:25 +02:00
P 5150 6150
F 0 "K642" H 5100 6150 60 0001 C CNN
F 1 "K46" H 5150 6050 60 0001 C CNN
F 2 "Footprint:Mx_700" H 5150 6150 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 6150 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 5150 6150
2017-10-17 00:47:04 +02:00
-1 0 0 1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K940
2017-06-14 19:41:04 +02:00
U 1 1 5938DCEC
2017-10-09 00:00:25 +02:00
P 7250 5550
F 0 "K940" H 7200 5550 60 0001 C CNN
F 1 "K49" H 7250 5450 60 0000 C CNN
F 2 "Footprint:Mx_100" H 7250 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7250 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7250 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KA40
2017-06-14 19:41:04 +02:00
U 1 1 5938E868
2017-10-09 00:00:25 +02:00
P 7950 5550
F 0 "KA40" H 7900 5550 60 0001 C CNN
F 1 "K4A" H 7950 5450 60 0000 C CNN
F 2 "Footprint:Mx_125" H 7950 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7950 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB40
2017-06-14 19:41:04 +02:00
U 1 1 5939E5DA
2017-10-09 00:00:25 +02:00
P 8650 5550
F 0 "KB40" H 8600 5550 60 0001 C CNN
F 1 "K4B" H 8650 5450 60 0000 C CNN
F 2 "Footprint:Mx_100" H 8650 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB41
2017-06-14 19:41:04 +02:00
U 1 1 5939E859
2017-10-09 00:00:25 +02:00
P 8650 5850
F 0 "KB41" H 8600 5850 60 0001 C CNN
F 1 "K4B" H 8650 5750 60 0001 C CNN
F 2 "Footprint:Mx_125" H 8650 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KB42
2017-06-14 19:41:04 +02:00
U 1 1 5939E96F
2017-10-09 00:00:25 +02:00
P 8650 6150
F 0 "KB42" H 8600 6150 60 0001 C CNN
F 1 "K4B" H 8650 6050 60 0001 C CNN
F 2 "Footprint:Mx_150" H 8650 6150 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 8650 6150 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 8650 6150
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC40
2017-06-14 19:41:04 +02:00
U 1 1 5939FBC5
2017-10-09 00:00:25 +02:00
P 9350 5550
F 0 "KC40" H 9300 5550 60 0001 C CNN
F 1 "K4C" H 9350 5450 60 0000 C CNN
F 2 "Footprint:Mx_100" H 9350 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K4C1
2017-06-14 19:41:04 +02:00
U 1 1 5939FDEB
2017-10-09 00:00:25 +02:00
P 9350 5850
F 0 "K4C1" H 9300 5850 60 0001 C CNN
F 1 "K4C" H 9350 5750 60 0001 C CNN
F 2 "Footprint:Mx_125" H 9350 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD40
2017-06-14 19:41:04 +02:00
U 1 1 593A0C81
2017-10-09 00:00:25 +02:00
P 10050 5550
F 0 "KD40" H 10000 5550 60 0001 C CNN
F 1 "K4D" H 10050 5450 60 0000 C CNN
F 2 "Footprint:Mx_125" H 10050 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD41
2017-06-14 19:41:04 +02:00
U 1 1 593A0EB4
2017-10-09 00:00:25 +02:00
P 10050 5850
F 0 "KD41" H 10000 5850 60 0001 C CNN
F 1 "K4D" H 10050 5750 60 0001 C CNN
F 2 "Footprint:Mx_150" H 10050 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW K241
2017-06-14 19:41:04 +02:00
U 1 1 5937F3D0
2017-10-09 00:00:25 +02:00
P 2350 5850
F 0 "K241" H 2300 5850 60 0001 C CNN
F 1 "K42" H 2350 5750 60 0001 C CNN
F 2 "Footprint:Mx_150" H 2350 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 2350 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 2350 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD20
2017-06-14 19:41:04 +02:00
U 1 1 5934A273
2017-10-09 00:00:25 +02:00
P 10050 2800
F 0 "KD20" H 10000 2800 60 0001 C CNN
F 1 "K2D" H 10050 2700 60 0000 C CNN
F 2 "Footprint:Mx_125" H 10050 2800 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 2800 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
F 5 "1.25 ENTER" H 10050 2800 60 0001 C CNN "Comment"
2017-10-09 00:00:25 +02:00
1 10050 2800
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KD31
2017-06-14 19:41:04 +02:00
U 1 1 5934BA33
2017-10-09 00:00:25 +02:00
P 10050 4450
F 0 "KD31" H 10000 4450 60 0001 C CNN
F 1 "K3D" H 10050 4350 60 0001 C CNN
F 2 "Footprint:Mx_175" H 10050 4450 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 10050 4450 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 10050 4450
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L KEYSW KC31
2017-06-14 19:41:04 +02:00
U 1 1 5934D411
2017-10-09 00:00:25 +02:00
P 9350 4450
F 0 "KC31" H 9300 4450 60 0001 C CNN
F 1 "K3C" H 9350 4350 60 0001 C CNN
F 2 "Footprint:Mx_100" H 9350 4450 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 9350 4450 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 9350 4450
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKD0
2017-06-14 19:41:04 +02:00
U 1 1 59314342
2017-10-09 00:00:25 +02:00
P 10350 750
F 0 "DKD0" H 10350 850 50 0001 C CNN
F 1 "DKD0" H 10350 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 10350 750 50 0001 C CNN
F 3 "" H 10350 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 10350 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D KDC0
2017-06-14 19:41:04 +02:00
U 1 1 59315073
2017-10-09 00:00:25 +02:00
P 9650 750
F 0 "KDC0" H 9650 850 50 0001 C CNN
F 1 "D0C" H 9650 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 9650 750 50 0001 C CNN
F 3 "" H 9650 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 9650 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKB0
2017-06-14 19:41:04 +02:00
U 1 1 593150EE
2017-10-09 00:00:25 +02:00
P 8950 750
F 0 "DKB0" H 8950 850 50 0001 C CNN
F 1 "D0B" H 8950 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8950 750 50 0001 C CNN
F 3 "" H 8950 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 8950 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKA0
2017-06-14 19:41:04 +02:00
U 1 1 5931516C
2017-10-09 00:00:25 +02:00
P 8250 750
F 0 "DKA0" H 8250 850 50 0001 C CNN
F 1 "D0A" H 8250 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8250 750 50 0001 C CNN
F 3 "" H 8250 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 8250 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK90
2017-06-14 19:41:04 +02:00
U 1 1 593151EB
2017-10-09 00:00:25 +02:00
P 7550 750
F 0 "DK90" H 7550 850 50 0001 C CNN
F 1 "D09" H 7550 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 7550 750 50 0001 C CNN
F 3 "" H 7550 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 7550 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK80
2017-06-14 19:41:04 +02:00
U 1 1 59315265
2017-10-09 00:00:25 +02:00
P 6850 750
F 0 "DK80" H 6850 850 50 0001 C CNN
F 1 "D08" H 6850 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6850 750 50 0001 C CNN
F 3 "" H 6850 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 6850 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK70
2017-06-14 19:41:04 +02:00
U 1 1 593152E6
2017-10-09 00:00:25 +02:00
P 6150 750
F 0 "DK70" H 6150 850 50 0001 C CNN
F 1 "D07" H 6150 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6150 750 50 0001 C CNN
F 3 "" H 6150 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 6150 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK40
2017-06-14 19:41:04 +02:00
U 1 1 59315370
2017-10-09 00:00:25 +02:00
P 4050 750
F 0 "DK40" H 4050 850 50 0001 C CNN
F 1 "D04" H 4050 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4050 750 50 0001 C CNN
F 3 "" H 4050 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 4050 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK30
2017-06-14 19:41:04 +02:00
U 1 1 59315563
2017-10-09 00:00:25 +02:00
P 3350 750
F 0 "DK30" H 3350 850 50 0001 C CNN
F 1 "D03" H 3350 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 3350 750 50 0001 C CNN
F 3 "" H 3350 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 3350 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK50
2017-06-14 19:41:04 +02:00
U 1 1 593155F9
2017-10-09 00:00:25 +02:00
P 4750 750
F 0 "DK50" H 4750 850 50 0001 C CNN
F 1 "D05" H 4750 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4750 750 50 0001 C CNN
F 3 "" H 4750 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 4750 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK6
2017-06-14 19:41:04 +02:00
U 1 1 593156A4
2017-10-09 00:00:25 +02:00
P 5450 750
F 0 "DK6" H 5450 850 50 0001 C CNN
F 1 "D60" H 5450 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 5450 750 50 0001 C CNN
F 3 "" H 5450 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 5450 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK20
2017-06-14 19:41:04 +02:00
U 1 1 59315732
2017-10-09 00:00:25 +02:00
P 2650 750
F 0 "DK20" H 2650 850 50 0001 C CNN
F 1 "D02" H 2650 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 2650 750 50 0001 C CNN
F 3 "" H 2650 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 2650 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK10
2017-06-14 19:41:04 +02:00
U 1 1 5931581F
2017-10-09 00:00:25 +02:00
P 1950 750
F 0 "DK10" H 1950 850 50 0001 C CNN
F 1 "D01" H 1950 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1950 750 50 0001 C CNN
F 3 "" H 1950 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 1950 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK0
2017-06-14 19:41:04 +02:00
U 1 1 593158B3
2017-10-09 00:00:25 +02:00
P 1250 750
F 0 "DK0" H 1250 850 50 0001 C CNN
F 1 "D00" H 1250 650 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1250 750 50 0001 C CNN
F 3 "" H 1250 750 50 0000 C CNN
2017-10-17 00:47:04 +02:00
1 1250 750
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKD1
2017-06-14 19:41:04 +02:00
U 1 1 5931B798
2017-10-09 00:00:25 +02:00
P 10350 1850
F 0 "DKD1" H 10350 1950 50 0001 C CNN
F 1 "D1D" H 10350 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 10350 1850 50 0001 C CNN
F 3 "" H 10350 1850 50 0000 C CNN
1 10350 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKC1
2017-06-14 19:41:04 +02:00
U 1 1 5931B79E
2017-10-09 00:00:25 +02:00
P 9650 1850
F 0 "DKC1" H 9650 1950 50 0001 C CNN
F 1 "D1C" H 9650 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 9650 1850 50 0001 C CNN
F 3 "" H 9650 1850 50 0000 C CNN
1 9650 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKB1
2017-06-14 19:41:04 +02:00
U 1 1 5931B7A4
2017-10-09 00:00:25 +02:00
P 8950 1850
F 0 "DKB1" H 8950 1950 50 0001 C CNN
F 1 "D1B" H 8950 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8950 1850 50 0001 C CNN
F 3 "" H 8950 1850 50 0000 C CNN
1 8950 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKA1
2017-06-14 19:41:04 +02:00
U 1 1 5931B7AA
2017-10-09 00:00:25 +02:00
P 8250 1850
F 0 "DKA1" H 8250 1950 50 0001 C CNN
F 1 "DA1" H 8250 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8250 1850 50 0001 C CNN
F 3 "" H 8250 1850 50 0000 C CNN
1 8250 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK91
2017-06-14 19:41:04 +02:00
U 1 1 5931B7B0
2017-10-09 00:00:25 +02:00
P 7550 1850
F 0 "DK91" H 7550 1950 50 0001 C CNN
F 1 "D19" H 7550 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 7550 1850 50 0001 C CNN
F 3 "" H 7550 1850 50 0000 C CNN
1 7550 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK81
2017-06-14 19:41:04 +02:00
U 1 1 5931B7B6
2017-10-09 00:00:25 +02:00
P 6850 1850
F 0 "DK81" H 6850 1950 50 0001 C CNN
F 1 "D18" H 6850 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6850 1850 50 0001 C CNN
F 3 "" H 6850 1850 50 0000 C CNN
1 6850 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK71
2017-06-14 19:41:04 +02:00
U 1 1 5931B7BC
2017-10-09 00:00:25 +02:00
P 6150 1850
F 0 "DK71" H 6150 1950 50 0001 C CNN
F 1 "D17" H 6150 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6150 1850 50 0001 C CNN
F 3 "" H 6150 1850 50 0000 C CNN
1 6150 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK41
2017-06-14 19:41:04 +02:00
U 1 1 5931B7C2
2017-10-09 00:00:25 +02:00
P 4050 1850
F 0 "DK41" H 4050 1950 50 0001 C CNN
F 1 "D14" H 4050 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4050 1850 50 0001 C CNN
F 3 "" H 4050 1850 50 0000 C CNN
1 4050 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK31
2017-06-14 19:41:04 +02:00
U 1 1 5931B7C8
2017-10-09 00:00:25 +02:00
P 3350 1850
F 0 "DK31" H 3350 1950 50 0001 C CNN
F 1 "D13" H 3350 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 3350 1850 50 0001 C CNN
F 3 "" H 3350 1850 50 0000 C CNN
1 3350 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK51
2017-06-14 19:41:04 +02:00
U 1 1 5931B7CE
2017-10-09 00:00:25 +02:00
P 4750 1850
F 0 "DK51" H 4750 1950 50 0001 C CNN
F 1 "D15" H 4750 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4750 1850 50 0001 C CNN
F 3 "" H 4750 1850 50 0000 C CNN
1 4750 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK61
2017-06-14 19:41:04 +02:00
U 1 1 5931B7D4
2017-10-09 00:00:25 +02:00
P 5450 1850
F 0 "DK61" H 5450 1950 50 0001 C CNN
F 1 "D16" H 5450 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 5450 1850 50 0001 C CNN
F 3 "" H 5450 1850 50 0000 C CNN
1 5450 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK21
2017-06-14 19:41:04 +02:00
U 1 1 5931B7DA
2017-10-09 00:00:25 +02:00
P 2650 1850
F 0 "DK21" H 2650 1950 50 0001 C CNN
F 1 "D12" H 2650 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 2650 1850 50 0001 C CNN
F 3 "" H 2650 1850 50 0000 C CNN
1 2650 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK11
2017-06-14 19:41:04 +02:00
U 1 1 5931B7E0
2017-10-09 00:00:25 +02:00
P 1950 1850
F 0 "DK11" H 1950 1950 50 0001 C CNN
F 1 "D11" H 1950 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1950 1850 50 0001 C CNN
F 3 "" H 1950 1850 50 0000 C CNN
1 1950 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK1
2017-06-14 19:41:04 +02:00
U 1 1 5931B7E6
2017-10-09 00:00:25 +02:00
P 1250 1850
F 0 "DK1" H 1250 1950 50 0001 C CNN
F 1 "D10" H 1250 1750 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1250 1850 50 0001 C CNN
F 3 "" H 1250 1850 50 0000 C CNN
1 1250 1850
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKD2
2017-06-14 19:41:04 +02:00
U 1 1 59346AE2
2017-10-09 00:00:25 +02:00
P 10350 2650
F 0 "DKD2" H 10350 2750 50 0001 C CNN
F 1 "D2D" H 10350 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 10350 2650 50 0001 C CNN
F 3 "" H 10350 2650 50 0000 C CNN
1 10350 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKC2
2017-06-14 19:41:04 +02:00
U 1 1 59346AE8
2017-10-09 00:00:25 +02:00
P 9650 2650
F 0 "DKC2" H 9650 2750 50 0001 C CNN
F 1 "D2C" H 9650 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 9650 2650 50 0001 C CNN
F 3 "" H 9650 2650 50 0000 C CNN
1 9650 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKB2
2017-06-14 19:41:04 +02:00
U 1 1 59346AEE
2017-10-09 00:00:25 +02:00
P 8950 2650
F 0 "DKB2" H 8950 2750 50 0001 C CNN
F 1 "D2B" H 8950 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8950 2650 50 0001 C CNN
F 3 "" H 8950 2650 50 0000 C CNN
1 8950 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKA2
2017-06-14 19:41:04 +02:00
U 1 1 59346AF4
2017-10-09 00:00:25 +02:00
P 8250 2650
F 0 "DKA2" H 8250 2750 50 0001 C CNN
F 1 "D2A" H 8250 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8250 2650 50 0001 C CNN
F 3 "" H 8250 2650 50 0000 C CNN
1 8250 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK92
2017-06-14 19:41:04 +02:00
U 1 1 59346AFA
2017-10-09 00:00:25 +02:00
P 7550 2650
F 0 "DK92" H 7550 2750 50 0001 C CNN
F 1 "D29" H 7550 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 7550 2650 50 0001 C CNN
F 3 "" H 7550 2650 50 0000 C CNN
1 7550 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK82
2017-06-14 19:41:04 +02:00
U 1 1 59346B00
2017-10-09 00:00:25 +02:00
P 6850 2650
F 0 "DK82" H 6850 2750 50 0001 C CNN
F 1 "D28" H 6850 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6850 2650 50 0001 C CNN
F 3 "" H 6850 2650 50 0000 C CNN
1 6850 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK72
2017-06-14 19:41:04 +02:00
U 1 1 59346B06
2017-10-09 00:00:25 +02:00
P 6150 2650
F 0 "DK72" H 6150 2750 50 0001 C CNN
F 1 "D27" H 6150 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6150 2650 50 0001 C CNN
F 3 "" H 6150 2650 50 0000 C CNN
1 6150 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK42
2017-06-14 19:41:04 +02:00
U 1 1 59346B0C
2017-10-09 00:00:25 +02:00
P 4050 2650
F 0 "DK42" H 4050 2750 50 0001 C CNN
F 1 "D24" H 4050 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4050 2650 50 0001 C CNN
F 3 "" H 4050 2650 50 0000 C CNN
1 4050 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK32
2017-06-14 19:41:04 +02:00
U 1 1 59346B12
2017-10-09 00:00:25 +02:00
P 3350 2650
F 0 "DK32" H 3350 2750 50 0001 C CNN
F 1 "D23" H 3350 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 3350 2650 50 0001 C CNN
F 3 "" H 3350 2650 50 0000 C CNN
1 3350 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK52
2017-06-14 19:41:04 +02:00
U 1 1 59346B18
2017-10-09 00:00:25 +02:00
P 4750 2650
F 0 "DK52" H 4750 2750 50 0001 C CNN
F 1 "D25" H 4750 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4750 2650 50 0001 C CNN
F 3 "" H 4750 2650 50 0000 C CNN
1 4750 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK62
2017-06-14 19:41:04 +02:00
U 1 1 59346B1E
2017-10-09 00:00:25 +02:00
P 5450 2650
F 0 "DK62" H 5450 2750 50 0001 C CNN
F 1 "D26" H 5450 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 5450 2650 50 0001 C CNN
F 3 "" H 5450 2650 50 0000 C CNN
1 5450 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK22
2017-06-14 19:41:04 +02:00
U 1 1 59346B24
2017-10-09 00:00:25 +02:00
P 2650 2650
F 0 "DK22" H 2650 2750 50 0001 C CNN
F 1 "D22" H 2650 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 2650 2650 50 0001 C CNN
F 3 "" H 2650 2650 50 0000 C CNN
1 2650 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK12
2017-06-14 19:41:04 +02:00
U 1 1 59346B2A
2017-10-09 00:00:25 +02:00
P 1950 2650
F 0 "DK12" H 1950 2750 50 0001 C CNN
F 1 "D21" H 1950 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1950 2650 50 0001 C CNN
F 3 "" H 1950 2650 50 0000 C CNN
1 1950 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK2
2017-06-14 19:41:04 +02:00
U 1 1 59346B30
2017-10-09 00:00:25 +02:00
P 1250 2650
F 0 "DK2" H 1250 2750 50 0001 C CNN
F 1 "D20" H 1250 2550 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1250 2650 50 0001 C CNN
F 3 "" H 1250 2650 50 0000 C CNN
1 1250 2650
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKD3
2017-06-14 19:41:04 +02:00
U 1 1 5935728F
2017-10-09 00:00:25 +02:00
P 10350 4050
F 0 "DKD3" H 10350 4150 50 0001 C CNN
F 1 "D3D" H 10350 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 10350 4050 50 0001 C CNN
F 3 "" H 10350 4050 50 0000 C CNN
1 10350 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKC3
2017-06-14 19:41:04 +02:00
U 1 1 59357295
2017-10-09 00:00:25 +02:00
P 9650 4050
F 0 "DKC3" H 9650 4150 50 0001 C CNN
F 1 "D3C" H 9650 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 9650 4050 50 0001 C CNN
F 3 "" H 9650 4050 50 0000 C CNN
1 9650 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKB3
2017-06-14 19:41:04 +02:00
U 1 1 5935729B
2017-10-09 00:00:25 +02:00
P 8950 4050
F 0 "DKB3" H 8950 4150 50 0001 C CNN
F 1 "D3B" H 8950 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8950 4050 50 0001 C CNN
F 3 "" H 8950 4050 50 0000 C CNN
1 8950 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKA3
2017-06-14 19:41:04 +02:00
U 1 1 593572A1
2017-10-09 00:00:25 +02:00
P 8250 4050
F 0 "DKA3" H 8250 4150 50 0001 C CNN
F 1 "D3A" H 8250 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8250 4050 50 0001 C CNN
F 3 "" H 8250 4050 50 0000 C CNN
1 8250 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK93
2017-06-14 19:41:04 +02:00
U 1 1 593572A7
2017-10-09 00:00:25 +02:00
P 7550 4050
F 0 "DK93" H 7550 4150 50 0001 C CNN
F 1 "D39" H 7550 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 7550 4050 50 0001 C CNN
F 3 "" H 7550 4050 50 0000 C CNN
1 7550 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK83
2017-06-14 19:41:04 +02:00
U 1 1 593572AD
2017-10-09 00:00:25 +02:00
P 6850 4050
F 0 "DK83" H 6850 4150 50 0001 C CNN
F 1 "D38" H 6850 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6850 4050 50 0001 C CNN
F 3 "" H 6850 4050 50 0000 C CNN
1 6850 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK73
2017-06-14 19:41:04 +02:00
U 1 1 593572B3
2017-10-09 00:00:25 +02:00
P 6150 4050
F 0 "DK73" H 6150 4150 50 0001 C CNN
F 1 "D37" H 6150 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6150 4050 50 0001 C CNN
F 3 "" H 6150 4050 50 0000 C CNN
1 6150 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK43
2017-06-14 19:41:04 +02:00
U 1 1 593572B9
2017-10-09 00:00:25 +02:00
P 4050 4050
F 0 "DK43" H 4050 4150 50 0001 C CNN
F 1 "D34" H 4050 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4050 4050 50 0001 C CNN
F 3 "" H 4050 4050 50 0000 C CNN
1 4050 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK33
2017-06-14 19:41:04 +02:00
U 1 1 593572BF
2017-10-09 00:00:25 +02:00
P 3350 4050
F 0 "DK33" H 3350 4150 50 0001 C CNN
F 1 "D33" H 3350 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 3350 4050 50 0001 C CNN
F 3 "" H 3350 4050 50 0000 C CNN
1 3350 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK53
2017-06-14 19:41:04 +02:00
U 1 1 593572C5
2017-10-09 00:00:25 +02:00
P 4750 4050
F 0 "DK53" H 4750 4150 50 0001 C CNN
F 1 "D35" H 4750 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4750 4050 50 0001 C CNN
F 3 "" H 4750 4050 50 0000 C CNN
1 4750 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK63
2017-06-14 19:41:04 +02:00
U 1 1 593572CB
2017-10-09 00:00:25 +02:00
P 5450 4050
F 0 "DK63" H 5450 4150 50 0001 C CNN
F 1 "D36" H 5450 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 5450 4050 50 0001 C CNN
F 3 "" H 5450 4050 50 0000 C CNN
1 5450 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK23
2017-06-14 19:41:04 +02:00
U 1 1 593572D1
2017-10-09 00:00:25 +02:00
P 2650 4050
F 0 "DK23" H 2650 4150 50 0001 C CNN
F 1 "D32" H 2650 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 2650 4050 50 0001 C CNN
F 3 "" H 2650 4050 50 0000 C CNN
1 2650 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK13
2017-06-14 19:41:04 +02:00
U 1 1 593572D7
2017-10-09 00:00:25 +02:00
P 1950 4050
F 0 "DK13" H 1950 4150 50 0001 C CNN
F 1 "D31" H 1950 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1950 4050 50 0001 C CNN
F 3 "" H 1950 4050 50 0000 C CNN
1 1950 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK3
2017-06-14 19:41:04 +02:00
U 1 1 593572DD
2017-10-09 00:00:25 +02:00
P 1250 4050
F 0 "DK3" H 1250 4150 50 0001 C CNN
F 1 "D30" H 1250 3950 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1250 4050 50 0001 C CNN
F 3 "" H 1250 4050 50 0000 C CNN
1 1250 4050
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK4
2017-06-14 19:41:04 +02:00
U 1 1 59377078
2017-10-09 00:00:25 +02:00
P 1250 5400
F 0 "DK4" H 1250 5500 50 0001 C CNN
F 1 "D40" H 1250 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1250 5400 50 0001 C CNN
F 3 "" H 1250 5400 50 0000 C CNN
1 1250 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK14
2017-06-14 19:41:04 +02:00
U 1 1 5937E4BD
2017-10-09 00:00:25 +02:00
P 1950 5400
F 0 "DK14" H 1950 5500 50 0001 C CNN
F 1 "D41" H 1950 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 1950 5400 50 0001 C CNN
F 3 "" H 1950 5400 50 0000 C CNN
1 1950 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK64
2017-06-14 19:41:04 +02:00
U 1 1 5938675D
2017-10-09 00:00:25 +02:00
P 5450 5400
F 0 "DK64" H 5450 5500 50 0001 C CNN
F 1 "D46" H 5450 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 5450 5400 50 0001 C CNN
F 3 "" H 5450 5400 50 0000 C CNN
1 5450 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK94
2017-06-14 19:41:04 +02:00
U 1 1 5938E25B
2017-10-09 00:00:25 +02:00
P 7550 5400
F 0 "DK94" H 7550 5500 50 0001 C CNN
F 1 "D49" H 7550 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 7550 5400 50 0001 C CNN
F 3 "" H 7550 5400 50 0000 C CNN
1 7550 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKB4
2017-06-14 19:41:04 +02:00
U 1 1 5938ECF3
2017-10-09 00:00:25 +02:00
P 8950 5400
F 0 "DKB4" H 8950 5500 50 0001 C CNN
F 1 "D4B" H 8950 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8950 5400 50 0001 C CNN
F 3 "" H 8950 5400 50 0000 C CNN
1 8950 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKA4
2017-06-14 19:41:04 +02:00
U 1 1 5938EE2D
2017-10-09 00:00:25 +02:00
P 8250 5400
F 0 "DKA4" H 8250 5500 50 0001 C CNN
F 1 "D4A" H 8250 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 8250 5400 50 0001 C CNN
F 3 "" H 8250 5400 50 0000 C CNN
1 8250 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKC4
2017-06-14 19:41:04 +02:00
U 1 1 593A0621
2017-10-09 00:00:25 +02:00
P 9650 5400
F 0 "DKC4" H 9650 5500 50 0001 C CNN
F 1 "D4C" H 9650 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 9650 5400 50 0001 C CNN
F 3 "" H 9650 5400 50 0000 C CNN
1 9650 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DKD4
2017-06-14 19:41:04 +02:00
U 1 1 593A16FD
2017-10-09 00:00:25 +02:00
P 10350 5400
F 0 "DKD4" H 10350 5500 50 0001 C CNN
F 1 "D4D" H 10350 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 10350 5400 50 0001 C CNN
F 3 "" H 10350 5400 50 0000 C CNN
1 10350 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
$Comp
2017-10-09 00:00:25 +02:00
L D DK24
2017-06-14 19:41:04 +02:00
U 1 1 5937F703
2017-10-09 00:00:25 +02:00
P 2650 5400
F 0 "DK24" H 2650 5500 50 0001 C CNN
F 1 "D42" H 2650 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 2650 5400 50 0001 C CNN
F 3 "" H 2650 5400 50 0000 C CNN
1 2650 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-06-14 19:41:04 +02:00
$EndComp
Wire Wire Line
650 1450 10600 1450
Connection ~ 1350 1450
Connection ~ 2050 1450
Connection ~ 2750 1450
Connection ~ 3450 1450
Connection ~ 4150 1450
Connection ~ 4850 1450
Connection ~ 5550 1450
Connection ~ 6250 1450
Connection ~ 6950 1450
Connection ~ 7650 1450
Connection ~ 8350 1450
Connection ~ 9050 1450
Wire Wire Line
2017-10-09 00:00:25 +02:00
650 6400 10600 6400
2017-06-14 19:41:04 +02:00
Connection ~ 1350 6400
Connection ~ 2050 6400
Connection ~ 4850 6400
Connection ~ 6950 6400
Connection ~ 7650 6400
Connection ~ 8350 6400
Connection ~ 9050 6400
Connection ~ 9750 6400
Wire Wire Line
650 2250 10600 2250
Wire Wire Line
2017-10-09 00:00:25 +02:00
650 3650 10600 3650
2017-06-14 19:41:04 +02:00
Wire Wire Line
650 5000 10600 5000
Connection ~ 9750 5000
Connection ~ 9750 3650
Connection ~ 9750 2250
Connection ~ 9050 2250
Connection ~ 8350 2250
Connection ~ 7650 2250
Connection ~ 6950 2250
Connection ~ 6250 2250
Connection ~ 5550 2250
Connection ~ 4850 2250
Connection ~ 4150 2250
Connection ~ 3450 2250
Connection ~ 2750 2250
Connection ~ 2050 2250
Connection ~ 2050 3650
Connection ~ 2750 3650
Connection ~ 3450 3650
Connection ~ 4150 3650
Connection ~ 4850 3650
Connection ~ 5550 3650
Connection ~ 6250 3650
Connection ~ 6950 3650
Connection ~ 7650 3650
Connection ~ 8350 3650
Connection ~ 9050 3650
Connection ~ 9050 5000
Connection ~ 8350 5000
Connection ~ 7650 5000
Connection ~ 6950 5000
Connection ~ 6250 5000
Connection ~ 5550 5000
Connection ~ 4850 5000
Connection ~ 4150 5000
Connection ~ 3450 5000
Connection ~ 2750 5000
Connection ~ 2050 5000
Connection ~ 1350 2250
Connection ~ 1350 3650
Connection ~ 1350 5000
Text GLabel 1250 5250 0 60 Input ~ 0
Col0
Text GLabel 1950 5250 0 60 Input ~ 0
Col1
Text GLabel 2650 5250 0 60 Input ~ 0
Col2
Text GLabel 5450 5250 0 60 Input ~ 0
Col6
Text GLabel 7550 5250 0 60 Input ~ 0
Col9
Text GLabel 8250 5250 0 60 Input ~ 0
ColA
Text GLabel 8950 5250 0 60 Input ~ 0
ColB
Text GLabel 9650 5250 0 60 Input ~ 0
ColC
Text GLabel 10350 5250 0 60 Input ~ 0
ColD
Wire Notes Line
10950 6500 500 6500
Wire Notes Line
10950 5100 500 5100
Text GLabel 1250 3900 0 60 Input ~ 0
Col0
Text GLabel 1950 3900 0 60 Input ~ 0
Col1
Text GLabel 2650 3900 0 60 Input ~ 0
Col2
Text GLabel 5450 3900 0 60 Input ~ 0
Col6
Text GLabel 7550 3900 0 60 Input ~ 0
Col9
Text GLabel 8250 3900 0 60 Input ~ 0
ColA
Text GLabel 8950 3900 0 60 Input ~ 0
ColB
Text GLabel 9650 3900 0 60 Input ~ 0
ColC
Text GLabel 10350 3900 0 60 Input ~ 0
ColD
Text GLabel 3350 3900 0 60 Input ~ 0
Col3
Text GLabel 4050 3900 0 60 Input ~ 0
Col4
Text GLabel 4750 3900 0 60 Input ~ 0
Col5
Text GLabel 6150 3900 0 60 Input ~ 0
Col7
Text GLabel 6850 3900 0 60 Input ~ 0
Col8
Wire Notes Line
10950 2400 10950 3750
Wire Notes Line
10950 3750 500 3750
Text GLabel 1250 2500 0 60 Input ~ 0
Col0
Text GLabel 1950 2500 0 60 Input ~ 0
Col1
Wire Notes Line
500 5150 10950 5150
Wire Notes Line
10950 5150 10950 6500
Wire Notes Line
500 6500 500 5150
Text GLabel 10350 2500 0 60 Input ~ 0
ColD
Wire Notes Line
500 3800 10950 3800
Wire Notes Line
10950 3800 10950 5100
Wire Notes Line
500 5100 500 3800
Wire Notes Line
10950 2400 500 2400
Wire Notes Line
500 2400 500 3750
Text GLabel 2650 2500 0 60 Input ~ 0
Col2
Text GLabel 3350 2500 0 60 Input ~ 0
Col3
Text GLabel 4050 2500 0 60 Input ~ 0
Col4
Text GLabel 4750 2500 0 60 Input ~ 0
Col5
Text GLabel 5450 2500 0 60 Input ~ 0
Col6
Text GLabel 6150 2500 0 60 Input ~ 0
Col7
Text GLabel 6850 2500 0 60 Input ~ 0
Col8
Text GLabel 7550 2500 0 60 Input ~ 0
Col9
Text GLabel 8250 2500 0 60 Input ~ 0
ColA
Text GLabel 8950 2500 0 60 Input ~ 0
ColB
Text GLabel 9650 2500 0 60 Input ~ 0
ColC
Wire Notes Line
10950 1600 10950 2350
Wire Notes Line
10950 2350 500 2350
Wire Notes Line
500 2350 500 1600
Text GLabel 10350 1700 0 60 Input ~ 0
ColD
Text GLabel 1250 1700 0 60 Input ~ 0
Col0
Text GLabel 1950 1700 0 60 Input ~ 0
Col1
Text GLabel 2650 1700 0 60 Input ~ 0
Col2
Text GLabel 3350 1700 0 60 Input ~ 0
Col3
Text GLabel 4050 1700 0 60 Input ~ 0
Col4
Text GLabel 4750 1700 0 60 Input ~ 0
Col5
Text GLabel 6150 1700 0 60 Input ~ 0
Col7
Text GLabel 6850 1700 0 60 Input ~ 0
Col8
Text GLabel 7550 1700 0 60 Input ~ 0
Col9
Text GLabel 8250 1700 0 60 Input ~ 0
ColA
Text GLabel 8950 1700 0 60 Input ~ 0
ColB
Text GLabel 9650 1700 0 60 Input ~ 0
ColC
Wire Notes Line
500 1600 10950 1600
Wire Notes Line
10950 500 10950 1550
Wire Notes Line
10950 1550 500 1550
Wire Notes Line
2017-10-17 00:47:04 +02:00
500 1550 500 500
2017-10-09 00:00:25 +02:00
Wire Notes Line
2017-10-17 00:47:04 +02:00
500 500 10950 500
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
650 900 650 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
1350 900 1350 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
10350 900 10350 1200
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
9750 900 9750 1450
Connection ~ 9750 1450
Connection ~ 9750 1200
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
9050 900 9050 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
8350 900 8350 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
7650 900 7650 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
6950 900 6950 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
6250 900 6250 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
5550 900 5550 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
4850 900 4850 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
4150 900 4150 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
3450 900 3450 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
2750 900 2750 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
2050 900 2050 1450
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
650 2000 650 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
1350 2000 1350 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
2050 2000 2050 2250
Text GLabel 5450 1700 0 60 Input ~ 0
Col6
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
2750 2000 2750 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
3450 2000 3450 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
4150 2000 4150 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
4850 2000 4850 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
5550 2000 5550 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
6250 2000 6250 2250
2017-06-14 19:41:04 +02:00
Wire Wire Line
2017-10-09 00:00:25 +02:00
6950 2000 6950 2250
Wire Wire Line
7650 2000 7650 2250
Wire Wire Line
8350 2000 8350 2250
Wire Wire Line
9050 2000 9050 2250
Wire Wire Line
9750 2000 9750 2250
Wire Wire Line
1250 2800 1250 3100
Connection ~ 1250 2800
Wire Wire Line
650 2800 650 3650
Connection ~ 650 3100
Wire Wire Line
1350 2800 1350 3650
Wire Wire Line
2050 2800 2050 3650
Wire Wire Line
2750 2800 2750 3650
Wire Wire Line
3450 2800 3450 3650
Wire Wire Line
4150 2800 4150 3650
Wire Wire Line
4850 2800 4850 3650
Wire Wire Line
10350 2800 10350 3400
Connection ~ 10350 3100
Connection ~ 10350 2800
Wire Wire Line
9750 2800 9750 3650
Connection ~ 9750 3100
Connection ~ 9750 3400
Wire Wire Line
9050 2800 9050 3650
Wire Wire Line
8350 2800 8350 3650
Wire Wire Line
7650 2800 7650 3650
Wire Wire Line
6950 2800 6950 3650
Wire Wire Line
6250 2800 6250 3650
Wire Wire Line
5550 2800 5550 3650
Wire Wire Line
1250 4200 1250 4450
Wire Wire Line
650 4200 650 5000
Wire Wire Line
9050 4200 9050 5000
Connection ~ 9050 4450
Wire Wire Line
9650 4200 9650 4750
Connection ~ 9650 4450
Wire Wire Line
9750 4200 9750 5000
Wire Wire Line
10350 4200 10350 4450
Connection ~ 9750 4450
Connection ~ 10350 4200
Connection ~ 9050 4750
Connection ~ 9650 4200
Wire Wire Line
8350 4200 8350 5000
Wire Wire Line
7650 4200 7650 5000
Wire Wire Line
6950 4200 6950 5000
Wire Wire Line
6250 4200 6250 5000
Wire Wire Line
5550 4200 5550 5000
Wire Wire Line
4850 4200 4850 5000
Wire Wire Line
4150 4200 4150 5000
Wire Wire Line
3450 4200 3450 5000
Wire Wire Line
2750 4200 2750 5000
Wire Wire Line
2050 4200 2050 5000
Wire Wire Line
1350 4200 1350 5000
Connection ~ 650 4450
Connection ~ 1250 4200
$Comp
L KEYSW KA41
U 1 1 5938EBE3
P 7950 5850
F 0 "KA41" H 7900 5850 60 0001 C CNN
F 1 "K4A" H 7950 5750 60 0001 C CNN
F 2 "Footprint:Mx_150" H 7950 5850 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 7950 5850 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-09 00:00:25 +02:00
1 7950 5850
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-10-09 00:00:25 +02:00
$EndComp
Connection ~ 1250 5550
Connection ~ 1950 5550
Connection ~ 2650 5550
Connection ~ 5450 5550
Connection ~ 8250 5550
Connection ~ 8950 5550
Connection ~ 9650 5550
Connection ~ 10350 5550
Wire Wire Line
10350 5550 10350 5850
Wire Wire Line
9650 5550 9650 5850
Wire Wire Line
9050 5550 9050 6400
Wire Wire Line
9750 5550 9750 6400
Wire Wire Line
8950 5550 8950 6150
Connection ~ 8950 5850
Wire Wire Line
8350 5550 8350 6400
Wire Wire Line
8250 5850 8250 5550
Wire Wire Line
7650 5550 7650 6400
Wire Wire Line
5450 5550 5450 6150
Connection ~ 5450 5850
Wire Wire Line
4850 5550 4850 6400
Wire Wire Line
2650 5550 2650 5850
Wire Wire Line
2050 5550 2050 6400
Wire Wire Line
1950 5550 1950 5850
Wire Wire Line
1350 5550 1350 6400
Wire Wire Line
1250 5550 1250 5850
Wire Wire Line
2017-10-09 00:00:25 +02:00
650 5550 650 6400
Connection ~ 650 5850
Connection ~ 1350 5850
Connection ~ 2050 5850
Connection ~ 4850 5850
Connection ~ 4850 6150
Wire Wire Line
2017-10-09 00:00:25 +02:00
6950 5550 6950 6400
Connection ~ 7650 5850
Connection ~ 8350 5850
Connection ~ 8350 6150
Connection ~ 9050 5850
Connection ~ 9750 5850
2017-10-12 00:07:58 +02:00
$Comp
L KEYSW K540
U 1 1 59DE9804
P 4450 5550
F 0 "K540" H 4400 5550 60 0001 C CNN
F 1 "K45" H 4450 5450 60 0000 C CNN
F 2 "Footprint:Mx_225" H 4450 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 4450 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-12 00:07:58 +02:00
1 4450 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-10-12 00:07:58 +02:00
$EndComp
$Comp
L KEYSW K740
U 1 1 59DE980F
P 5850 5550
F 0 "K740" H 5800 5550 60 0001 C CNN
F 1 "K47" H 5850 5450 60 0000 C CNN
F 2 "Footprint:Mx_275" H 5850 5550 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5850 5550 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-12 00:07:58 +02:00
1 5850 5550
2017-10-17 00:47:04 +02:00
1 0 0 -1
2017-10-12 00:07:58 +02:00
$EndComp
Text GLabel 4750 5250 0 60 Input ~ 0
Col5
Text GLabel 6150 5250 0 60 Input ~ 0
Col7
$Comp
L D DK74
U 1 1 59DE981E
P 6150 5400
F 0 "DK74" H 6150 5500 50 0001 C CNN
F 1 "D47" H 6150 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 6150 5400 50 0001 C CNN
F 3 "" H 6150 5400 50 0001 C CNN
2017-10-12 00:07:58 +02:00
1 6150 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-10-12 00:07:58 +02:00
$EndComp
$Comp
L D DK54
U 1 1 59DE9829
P 4750 5400
F 0 "DK54" H 4750 5500 50 0001 C CNN
F 1 "D45" H 4750 5300 50 0001 C CNN
F 2 "Footprint:D_SOD123" H 4750 5400 50 0001 C CNN
F 3 "" H 4750 5400 50 0001 C CNN
2017-10-12 00:07:58 +02:00
1 4750 5400
2017-10-17 00:47:04 +02:00
0 -1 -1 0
2017-10-12 00:07:58 +02:00
$EndComp
$Comp
L KEYSW K643
U 1 1 59DE985B
P 5150 5700
F 0 "K643" H 5100 5700 60 0001 C CNN
F 1 "K46" H 5150 5600 60 0001 C CNN
F 2 "Footprint:Mx_100" H 5150 5700 60 0001 C CNN
F 3 "https://search.kemet.com/component-edge/download/datasheet/C0805C220J5GACTU.pdf" H 5150 5700 60 0001 C CNN
F 4 "MX1A-C1NW" H 1650 900 60 0001 C CNN "manf#"
2017-10-12 00:07:58 +02:00
1 5150 5700
-1 0 0 1
2017-10-12 00:07:58 +02:00
$EndComp
Wire Wire Line
4150 5550 4150 6400
Connection ~ 4150 6400
Wire Wire Line
5550 5550 5550 6400
Connection ~ 5550 6400
Connection ~ 4850 5700
Connection ~ 5450 5700
NoConn ~ -200 1000
2017-06-14 19:41:04 +02:00
$EndSCHEMATC