168 lines
5.9 KiB
Markdown
168 lines
5.9 KiB
Markdown
![LED location](/img/led/led_location.png)
|
|
|
|
## On-Board LEDs
|
|
|
|
| LED number | Color | Software control | Remarks |
|
|
|------------|-------|------------------|---------|
|
|
| LED1 | Green | Yes | Active-low |
|
|
| LED2 | Red | Yes | Active-low |
|
|
| LED3 | Green | Yes | Active-low |
|
|
| LED4 | Green | Yes | Active-low |
|
|
| LED5 | Green | Yes | Active-low |
|
|
| LED6 | Green | Yes | Active-low |
|
|
| LED7 | Green | Yes | Active-low |
|
|
| LED8 | Green | No | Power indicator |
|
|
|
|
!!! info
|
|
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
|
|
|
|
## Expansion Panel (J18)
|
|
|
|
Helios4 board was designed to either use the on-board LEDs or use a custom expansion panel (not-available).
|
|
If you wish to use the header, insure to switch to OFF the Dip Switch SW2.
|
|
|
|
![Dipswitch LED](/img/led/dipswitch_led_off.png)
|
|
|
|
### Pinout Table
|
|
|
|
![J18 Pinout](/img/led/gpio_pinout_j18.png)
|
|
|
|
| Pin | LED number | Remarks |
|
|
|-----|------------|---------|
|
|
| 1 | - | 3.3V supply |
|
|
| 2 | - | Not connected |
|
|
| 3 | LED1 | Active-low |
|
|
| 4 | LED2 | Active-low |
|
|
| 5 | LED3 | Active-low |
|
|
| 6 | LED4 | Active-low |
|
|
| 7 | LED5 | Active-low |
|
|
| 8 | LED6 | Active-low |
|
|
| 9 | LED7 | Active-low |
|
|
| 10 | - | GND |
|
|
|
|
!!! info
|
|
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
|
|
|
|
### Wiring Diagram
|
|
|
|
Since the signals to control the LEDs are active low, connect the pin to LED's cathode.
|
|
Below a wiring diagram example.
|
|
|
|
![Wiring Example](/img/led/led_expansion_wiring_diagram.png)
|
|
|
|
|
|
## LED under Linux
|
|
|
|
| LED | Name | Default Trigger | Remarks |
|
|
|------|----------------------|-----------------|---------|
|
|
| LED1 | helios4:green:status | heartbeat | Blinking periodically |
|
|
| LED2 | helios4:red:fault | none | See [Configuring Fault LED](#configuring-fault-led) |
|
|
| LED3 | helios4:green:ata1 | ata1 | Blinking on SATA1 activity |
|
|
| LED4 | helios4:green:ata2 | ata2 | Blinking on SATA2 activity |
|
|
| LED5 | helios4:green:ata3 | ata3 | Blinking on SATA3 activity |
|
|
| LED6 | helios4:green:ata4 | ata4 | Blinking on SATA4 activity |
|
|
| LED7 | helios4:green:usb | usb-host | Blinking on USB activity, any port |
|
|
|
|
!!! note
|
|
**ata** trigger requires additional patch to mainline kernel. The patch can be found [here](/files/led/libata_leds_trigger_mvebu.patch). **Armbian** builds are already patched, so no action is required.
|
|
|
|
The LEDs can be accessed under LEDs class in *sysfs*.
|
|
|
|
```
|
|
root@helios4:~/# ls -l /sys/class/leds/
|
|
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata1 -> ../../devices/platform/io-leds/leds/helios4:green:ata1
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata2 -> ../../devices/platform/io-leds/leds/helios4:green:ata2
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata3 -> ../../devices/platform/io-leds/leds/helios4:green:ata3
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata4 -> ../../devices/platform/io-leds/leds/helios4:green:ata4
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:status -> ../../devices/platform/system-leds/leds/helios4:green:status
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:usb -> ../../devices/platform/io-leds/leds/helios4:green:usb
|
|
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:red:fault -> ../../devices/platform/system-leds/leds/helios4:red:fault
|
|
|
|
```
|
|
|
|
### LEDs Trigger
|
|
|
|
- none
|
|
|
|
No automatic trigger. Manually control the LED by manipulating "brightness".
|
|
More info see [Configuring LED trigger](#configuring-led-trigger).
|
|
|
|
- heartbeat
|
|
|
|
LED "double" flashes at a load average based rate. The interval might change during heavy load.
|
|
If the LED no longer blinks, it means the system is locked-up or hung and has to be reset.
|
|
|
|
- ata*N*
|
|
|
|
LED blinks on any read/write activity at specific SATA port.
|
|
|
|
- usb-host
|
|
|
|
LED blinks on USB activity at any port.
|
|
|
|
- panic
|
|
|
|
This trigger allows LEDs to be configured to blink on a kernel panic.
|
|
|
|
- timer
|
|
|
|
This allows LEDs to be controlled by a programmable timer via *sysfs*. delay_on to set how long
|
|
the LED turned on and delay_off to set how long the LED turned off.
|
|
|
|
|
|
### Configuring LED trigger
|
|
|
|
To configure, simply set the trigger type. For example to set Status LED triggered by timer
|
|
|
|
```
|
|
echo timer | sudo tee -a /sys/class/leds/helios4\:green\:status/trigger
|
|
```
|
|
|
|
Some of the triggers may expose additional parameters that can be configured further.
|
|
|
|
On **none** trigger, to turn ON the LED set the brightness bigger than 0.
|
|
|
|
```
|
|
echo 1 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
|
|
```
|
|
|
|
and to turn OFF the LED set the brightness to 0.
|
|
|
|
```
|
|
echo 0 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
|
|
```
|
|
|
|
On **timer** trigger, it will exposed *delay_on* and *delay_off* with default value of 0.5 seconds for both.
|
|
To change the delay, set the respective parameter (value in milliseconds)
|
|
|
|
```
|
|
echo 1000 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_on
|
|
echo 200 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_off
|
|
```
|
|
|
|
!!! note
|
|
The changes is not retained across reboot. Use startup script or udev rules to make it permanent.
|
|
|
|
### Configuring Fault LED
|
|
|
|
While other LEDs are preconfigured, the fault LED remains unconfigured (trigger:**none**).
|
|
|
|
#### 1. As Kernel Panic Indicator
|
|
|
|
To configure the LED as Kernel panic indicator, set the trigger to **panic**. However this functionality might be redundant with Status LED, since if a kernel panic occurs and/or system hangs, the Status LED will no longer blink.
|
|
|
|
To trigger kernel panic to test the LED, run
|
|
```
|
|
echo c > /proc/sysrq-trigger
|
|
```
|
|
|
|
!!! warning
|
|
Triggering kernel panic can lead to data loss. Use with caution!
|
|
|
|
#### 2. As RAID Fault Indicator
|
|
|
|
To configure the LED as RAID fault indicator, please refer to [MDADM: Configure Fault LED](/mdadm/#configure-fault-led)
|
|
|
|
!!! note
|
|
On Armbian builds, this is the default setting for fault LED.
|