UPS (Uninterruptible Power Supply)

Helios64 provides a built-in UPS feature to protect your data from unexpected power loss. The feature requires an additional Li-Ion Battery to be connected to header J9 .

J9 Location

Feature

When system detects AC power loss, the system will switch instantly to battery mode. The system is able to fully run (including HDDs) on battery for up to 15 min. During that time, if AC power comes back, system will switch back to AC power mode. Else, if AC power is not resuming and battery voltage reach a certain low threshold, the system will automatically trigger graceful shutdown or hibernation (system-to-disk).

Li-Ion Battery

As part of Helios64 accessories, we provide a specially designed Li-Ion Battery for the UPS feature.

Li-Ion Battery

The actual cells of the this battery pack is the Panasonic NCR18650BD, we use 2x cells in 2S1P configuration. The battery pack is equipped with a thermistor to monitor the cell temperature.

The battery pack is rated 7.4V 3200mAh (23.68Wh) with max continuous discharge of 10A.

!!! Info It's possible for users to build their own battery if they respect the same above specification and pinout.

J9 Header Pinout

j9 Pinout

Pin Name
1 Thermistor
2 Battery +
3 Battery +
4 GND
5 Battery -
6 Battery -

Charge Management

Battery charge is fully managed by hardware, no software required. Charging function still operates when system is powered off. Helios64 board provides a visual charging indicator on LED9.

LED State Description
On Charging
Off Charge complete
Blinking Fault / Battery Absent